About MoxaProductsSolutionsSupport & ServiceNews & EventsWhere to BuyPartner Zone

You are here: Home > Products > Wireless and Cellular Communications > Industrial GSM/GPRS Modem > OnCell G3100 Series  
OnCell G3100 Series New!
Industrial quad-band GSM/GPRS/EDGE IP modem
Quickview
View Larger Picture
Features Datasheet (PDF)
Specifications
Ordering Information  
Cellular M2M Overview

Universal quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
Choice of operation modes, including TCP Server, TCP Client, UDP, Real COM driver, and RFC2217
Secure modes for TCP Server, TCP Client, and Real COM
Versatile GSM/GPRS/EDGE connection modes
 
 
Introduction
 

The OnCell G3100 industrial RS-232 or RS-232/422/485 GSM/GPRS/EDGE IP modems are designed to transmit data and short messages (SMS) over GSM/GPRS/EDGE cellular networks. The Real COM operation mode automatically generates a virtual COM port to match serial ports supported by the OnCell G3100, allowing you to communicate with remote serial devices. The OnCell G3100's CPU comes pre-installed with the TCP/IP protocol suite to transmit data back and forth between the serial device and cellular TCP/IP network. It also comes with a built-in relay output that can be configured to indicate the priority of events when notifying or warning engineers in the field, and the two digital inputs allow you to connect basic I/O devices, such as sensors, to the cellular network. The G3100 can be mounted on a DIN-rail, and the 12 to 48 VDC power input has 2 KV EFT/Surge protection to allow the use of different types of field power source. The serial ports are also protected by 15 KV ESD line protection to keep your system safe from unexpected electrical discharges.

More info >>

Back to Top
Features
Redundant DC power input
LED indicators for status and signal level
2 digital inputs and 1 relay output
Choice of confi guration methods, including web console , serial console, and Telnet
DIN-Rail
 
Back to Top

Specifications
Hardware
CPU

MOXA ART CPU, 192 MHz

RAM
8 MB
Flash ROM
4 MB
 
LAN Interface
Ethernet
10/100 Mbps, RJ45 connector, Auto MDI/MDIX
Magnetic Isolation Protection
1.5 KV built-in
 
Cellular Interface
Standards
GSM/GPRS/EDGE
Band Options
Quad-band 850/900 and 1800/1900 MHz
GPRS Multi-slot Class
Class 12
GPRS Terminal Device Class
Class B
GPRS Coding Schemes
CS1 to CS4
Tx Power
1 watt GSM 1800/1900, 2 watts EGSM 850/900
SIM Control
3 V
 
Serial Interface
Serial Standards

G3110: RS-232 (DB9 male connector)
G3150: RS-232 (DB9 male connector), RS-422/485 (5-pin terminal block connector)

Number of Ports
1
ESD Protection
15 KV
Power EFT/Surge Protection
2 KV
 
Serial Communication Parameters
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2 (when parity = None)
Parity
None, Even, Odd, Space, Mark
Flow Control
RTS/CTS, XON/XOFF
Baudrate
50 bps to 921.6 Kbps
 
Serial Signals
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
 
I/O Interface
Alarm Contact
1 relay output with current carrying capacity of 1A @ 24 VDC
Digital Input
2 inputs electrically isolated from the electronics Software
Network Protocols
ICMP, TCP/IP, UDP, DHCP, Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, ARP
Operation Modes
RealCOM, Secure RealCOM, TCP Server, Secure TCP Server, TCP Client, Secure TCP Client, UDP, RFC2217, Ethernet Modem, SMS Tunnel
Confi guration and Management Options
SNMP MIB-II, v3, DDNS, IP Report, Web/Telnet/Serial Console, Serial Logging
Authentication
Local user-name and password
Security
Accessible IP list
Utilities
Provided for Windows 98, ME, NT, 2000, XP, 2003, XP x64, 2003 x64, Vista x64
Security
Accessible IP list
Utilities
Provided for Windows 98, ME, NT, 2000, XP, 2003, XP x64, 2003 x64, Vista x64
Windows Drivers
Windows 98, ME, NT, 2000, XP, 2003, XP x64, 2003 x64, Vista x64
Fixed TTY Drivers
SCO Unix, SCO OpenServer 5, SCO OpenServer 6, UnixWare 7, SVR4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD 5, FreeBSD 6
Windows Drivers
Windows 98, ME, NT, 2000, XP, 2003, XP x64, 2003 x64, Vista x64
Fixed TTY Drivers
SCO Unix, SCO OpenServer 5, SCO OpenServer 6, UnixWare 7, SVR4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD 5, FreeBSD 6
Real TTY Drivers
Linux kernels 2.2.x, 2.4.x, 2.6.x
 
Physical Characteristics
Housing
Aluminum, providing IP30 protection
 
Environmental Limits
Operating Temperature
0 to 55°C (32 to 131°F)
Operating Humidity
5 to 95% RH
Storage Temperature
-40 to 75°C (-40 to 167°F)
 
Power Requirements
Input Voltage
12 to 48 VDC
Data Link
585 to 1185 mA (peak) @ 12 V
 
Regulatory Approvals
Safety
UL: UL60950
TÜV: EN60950
EMC
CE: EN55022 Class A / EN55024
FCC: FCC part 15 subpart B, Class A
EN61000-4-2 (ESD) Level 4
EN61000-4-3 (RS) Level 3
EN61000-4-4 (EFT) Level 4
EN61000-4-5 (Surge) Level 3
EN61000-4-8 Level 3
EN61000-4-12 Level 3
RF
FCC Part22H
FCC PART24E
EN301 489-1
EN301 489-7
EN301 511
 
Warranty
Warranty Period
5 years
Details
See 1g.moxa.com/warranty
 

Ordering Information
 
OnCell G3110
1-port RS-232 to GSM/GPRS/EDGE IP modem
OnCell G3150
1-port RS-232/422/485 to GSM/GPRS/EDGE IP modem
 
Optional Accessories
Power Adapter
1.2 A (or above) @ 12 V
See Appendix A
See Appendix A
Quad-band Antennas (impedance = 50 ohms)
  • ANT-CQB-O-0-3m: Omni 0dBi/10cm, magnetic SMA antenna, 3 m
  • ANT-CQB-O-3-3m: Omni 3dBi/25cm, magnetic SMA antenna, 3 m
  • ANT-CQB-O-5-3m: Omni 5dBi/37cm, magnetic SMA antenna, 3 m
  •  

    Home | About Moxa | Products | Solutions | Support & Service | News & Events | Partner Zone | Where to Buy | Contact Moxa | Sitemap